ads

Information About Single Incision Laparoscopic Surgery

By Margaret Bailey


Approaches to surgical operation are changing and evolving mostly because of major technological advancements that are being made in various fields including surgical medicine. Single incision laparoscopic surgery is often referred to using the abbreviation SILS, but it also has many other names. Among the names SILS goes by are Single-port laparoscopy, single-port access surgery (SPA), Single-access endoscopic surgery (SAES), and single-port incisionnless conventional equipment-using surgery (SPICES). Other names include natural-orifice trannsumbilical surgery (NOTUS), one-port umbilical surgery (OPUS), and laparo-endoscopic singular-site surgery (LESS).

SILS is a technique in laparoscopic surgery that is still relatively new owing to its recent development. It is classified as a minimally invasive surgical operation because most of the process is done through one entry point. In most cases, the navel serves as the entry point into interior of the patient. Thus, because only one entry point is used, only a single tiny scar is left behind after the process has been completed.

The entry point can be made into a 20 mm or 11mm incision. The importance of utilizing only a single entry point is to minimize pain and scarring. This is opposed to traditional laparoscopic surgical procedure in which multiple entry point are made and used. New York is home to some of the most well-trained and qualified specialists in this kind of procedure. Thus it would be a great place to consider visiting if one needs such a process done to them.

There are two categories of specialized surgical equipment used by SILS. The two broad categories are hand instruments and access ports instruments. Access ports instruments are of various types including the GelPOINT system, QuadPort+, TriPort15, Uni-X, SILS device, and TriPort+. The manufacturers of these instruments are different.

Conversely, there are three key configurations of hand instruments in use. They include articulating, pre-bent rigid, and standard configurations. It has taken over the past thirty years to develop standard hand tools. They are made with rigid design. The SPL reduced triangulation instrument problem was solved by the development of articulation hand instruments.

The choice of whether or not to use articulating or standard instruments usually lies with the surgeons. There are a few factors that influence the decision. Among these influential factors are access port used, cost, and surgical skills of a surgeon. Articulating instruments are very costly when compared to standard instruments. This procedure is made safer and more effective by the use of specialized instruments.

The degree of awareness of SILS among surgeons is very high. However, the performance of SILS is limited to a few surgeons owing to its high level of complexity, limited space of access, and the use of specialized instruments. Surgical doctors who perform the procedure have to be highly skills and trained in surgical processes. That has promoted negative perception from the public and limited indulgence in the process.

SILS can be applied in performing a wide range of surgeries. Some of the most the include colectomy, sleeve gastrectomy, hysterectomy, appendectomy, nephrectomy, adjustable gastric banding, and sacrocolpopexy among many others. In the United States, standard instruments dominate this field of surgical operation as opposed to specialized instruments.




About the Author:



0 comments: