Important Safety Information To Consider When Applying Intensity Twin Stim III

By Cornelia Reyes


It is sensible to first have an understanding and the workings of InTENSity Twin Stim III before engaging on a conversation on the significant safety information to consider. If the information is not taken into consideration, the patient my suffer survivor effects which are dangerous. InTENSity Twin Stim III is an electric device which physicians use to help patients to relive pain. The device works by sending gentle electric currents to the muscles in the skin which is painful.

The following are some of the important safety information to consider. The device should only be handled by a physician who is licensed to handle it. The device do not have any curative value to talk off and the long term effect are not known.

Patients with known sensitivity to the carotid sinus reflex should not use the device on the carotid sinus nerve. This is for the reason that can cause effect to the nerves. If the patient is having pain in areas such as the neck and the mouths, an alternative pain reliever should be used.

It should also not be used over carotid sinus nerve especially when the patient d is having a known sensitivity to the carotid sinus reflex. It should also not be applied to areas such as mouth and neck. This is because it may make the patient to have difficulty in breathing. It should also not be applied transthoracally. This is because if it is applied transthoracally, it may lead to introduction of some electrical current to the heart. This may be very dangerous to the patient as it may cause cardiac arrhythmias.

The stimulation should not be allowed to occur if the patient is connected to a high frequency surgical equipment. If the stimulation is allowed to take place, the high frequency surgical equipment is likely to cause burn injuries to the skin.

It should also not be used in the vicinity of shortwave or microwave therapy equipment. This is because it may affect the power output of the stimulator. It must not be used in an environment with high humidity. Examples of environment with high humidity includes the bathroom, the wash room or even when having a bath.

It is also necessary to note that it is not recommended to be used on patients suffering from any heart disease on any skin are close to the heart. This is to prevent that the patient from suffering cardiac arrest. The physician using the device must ensure that the skin are is clean and dry.

It should only be applied to skin areas which are dry clean and which are not broken. The electrodes must also be kept separated during the treatment. These are some of the important safety information to consider when applying InTENSity Twin Stim III